List of Fragment Analysis Services
Product No. |
Name of Service |
Service Requirements |
Turnaround Time |
Standard Fragment Analysis Services |
|||
SS3001 |
Fragment Analysis with Run Report |
Customers to submit fluorescently label PCR products in tube/ strips. 1st BASE to perform electrophoresis and data analysis within the expected fragment sizes. |
3-4 working days |
SS3002 |
Fragment Analysis with Run Report, 96-well format
|
Service like above (SS3001), except samples submitted in 96-well plates. 95 samples/ plate; leave H12 empty for control. |
3-4 working days |
SS3003 |
Fragment Analysis without Run Report |
Customers to submit fluorescently label PCR products in tube/ strips. 1st BASE to perform electrophoresis and raw data extraction without analysis. |
2-3 working days |
SS3004 |
Fragment Analysis without Run Report, 96-well format
|
Service like above (SS3003), except samples submitted in 96-well plates. 95 samples/ plate; leave H12 empty for control. |
2-3 working days |
SS3012 |
Fragment Analysis with Run Report, without spectral optimization
|
Customers to submit properly diluted fluorescently label PCR products in tube/ strips. 1st BASE takes 2µL of the diluted DNA for electrophoresis and analyse data within the expected fragment sizes. This is designed to meet the needs of experienced users. Dilution is typically between 1µL:3µL to 1µL:90µL (PCR template:dH20). |
1 to 2 working days |
SS3013 |
Fragment Analysis with Run Report, without spectral optimization, 96-well format |
Service like above (SS3012), except samples submitted in 96-well plates. 95 samples/ plate; leave H12 empty for control. |
1 to 2 working days |
SS3014 |
Fragment Analysis without Run Report, without spectral optimization
|
Customers to submit properly diluted fluorescently label PCR products in tube/ strips. 1st BASE takes 2µL of the diluted DNA for electrophoresis and extracts raw data without analysis. This is designed to meet the needs of experienced users. Dilution is typically between 1µL:3µL to 1µL:90µL (PCR template:dH20). |
1 to 2 working days |
SS3015 |
Fragment Analysis without Run Report, without spectral optimization, 96-well format
|
Service like above (SS3014), except samples submitted in 96-well plates. 95 samples/ plate; leave H12 empty for control. |
1 to 2 working days |
SS3016 |
FA Ready-to-load with Run Report |
Customers to submit properly diluted fluorescently label PCR products with Hi-Di™ Formamide in tube/ strips. 1st BASE loads the mixture directly to Genetic Analyzer and analyse data within the expected fragment sizes. This is designed to meet the needs of experienced users. We only accept Applied Biosystems® GS500-ROX or GS500-LIZ size standards. |
1 to 2 working days |
SS3017 |
FA Ready-to-load in 96-well format with Run Report
|
Service like above (SS3016), except samples submitted in 96-well plates. 95 samples/ plate; leave H12 empty for control. |
1 to 2 working days |
SS3018 |
FA Ready-to-load without Run Report
|
Customers to submit properly diluted fluorescently label PCR products with Hi-Di™ Formamide in tube/ strips. 1st BASE loads the mixture directly to Genetic Analyzer and extracts raw data without analysis. This is designed to meet the needs of experienced users. We only accept Applied Biosystems® GS500-ROX or GS500-LIZ size standards. |
1 to 2 working days |
SS3019 |
FA Ready-to-load without Run Report, 96-well format
|
Service like above (SS3018), except samples submitted in 96-well plates. 95 samples/ plate; leave H12 empty for control. |
1 to 2 working days |
Sample Preparation and Quantification Service |
|||
SS3006 |
FA Spectral Optimization - Charge per first labelled primer/ locus.
|
Before loading, 3 types of Dilution Factor (DF) will be tested on the labelled sample(s) to get the optimum DF for data analysis. To opt out of this service, please provide DF for each labelled primer. |
2 working days |
SS3007 |
FA Spectral Optimization - Charge per each add-on labelled primer.
|
Before loading, 3 types of Dilution Factor (DF) will be tested on labelled sample(s) to get the optimum DF for data analysis. To opt out of this service, please provide DF for each labelled primer. |
2 working days |
SS3008 |
FA Spectral Optimization - Ready Multiplexed Sample.
|
Before loading, 3 types of Dilution Factor (DF) will be tested on 3 multiplexed samples to get the optimum DF for data analysis. To opt out of this service, please provide DF for each multiplexed sample. |
2 working days |
SS3005 |
Fragment Analysis Re-Load - Single Well/ Tube
|
Where spectral optimization is not ordered together with any standard fragment analysis, each request of reload will be chargeable. |
2 working days |
SS3010 |
Fragment Analysis Sample Quantification - By Agarose Gel |
This service allows customers to skip the hassle of gel electrophoresis to estimate Dilution Factor of each sample before fragment analysis.
Charge per sample. |
1 working day |
Product No. |
Service Name and Description |
Turnaround Time |
SS3100 |
Human Cell Line Authentication Genetic profiling of species specified short tandem repeat (STR) markers Deliverable: Report and raw loci calls |
3 to 5 working days |